Our product range includes a wide range of 2500 kva distribution transformer, 315 kva distribution transformer, 500 kva distribution transformer, 3-phase oil-cooled 400 kva distribution transformer, 2000 kva distribution transformer and 800 kva distribution transformer.
SERVOKON make, 2500 KVA Three Phase POWER TRANSFORMER With All other Standard accessories.
Make SERVOKON Capacity 2500 KVA Input Voltage 33 KV Output Voltage 11 KV Number of Phase 3 Phase Applicable Standard BIS 1180-2 as per new ammendment Number of Winding 2 Winding Type of Installation Outdoor Type Frequency 50 Hz Method of Cooling ONAN Terminal Arrangement Bare Bushing for HV Side & for LV Side Vector Group Dyn11 Designed Ambient Temperature 50° C Temperature Rise of Oil 40° C Temperature Rise of Winding 45° C Impedance 4.50% (Subject to +/-10% Tolerance) Transformer Oil "A Grade" tested & certified as per IS:335 Standard. Total Losses at 50% Load As per IS standard Total Losses at 100% Load As per IS standard Copper "Sterlite" make- 99.9% Pure Electrolytic Grade. Tapping Mode Off Circuit Tap Changer Basic Insulation Level for HV 75 KVpeak / 28KVrms Basic Insulation Level for LV - / 3 KVrms
SERVOKON make, Three Phase DISTRIBUTION TRANSFORMER With All other Standard accessories BIS 1180 L-2
Make SERVOKON Capacity 315 Input Voltage 11 KV Output Voltage 433 Volts Number of Phase 3 Phase Applicable Standard BIS 1180 L-2 Number of Winding 2 Winding Type of Installation Outdoor Type Frequency 50 Hz Method of Cooling ONAN Terminal Arrangement Bare Bushing for HV Side & for LV Side Vector Group Dyn11 Designed Ambient Temperature 50° C Temperature Rise of Oil 40° C Temperature Rise of Winding 45° C Impedance 4.50% (Subject to +/-10% Tolerance) Transformer Oil "A Grade" tested & certified as per IS:335 Standard. Total Losses at 50% Load As per IS Standard Total Losses at 100% Load As per IS Standard Copper "Sterlite" make- 99.9% Pure Electrolytic Grade. Tapping Mode Off Circuit Tap Changer Basic Insulation Level for HV 75 KVpeak / 28KVrms Basic Insulation Level for LV - / 3 KVrms
SERVOKON make, 500 KVA Three Phase DISTRIBUTION TRANSFORMER With All other Standard accessories
Make SERVOKON Capacity 500 KVA Input Voltage 11 KV Output Voltage 433 Volts Number of Phase 3 Phase Applicable Standard BIS 1180-2 Number of Winding 2 Winding Type of Installation Outdoor Type Frequency 50 Hz Method of Cooling ONAN Terminal Arrangement Bare Bushing for HV Side & for LV Side Vector Group Dyn11 Designed Ambient Temperature 50° C Temperature Rise of Oil 40° C Temperature Rise of Winding 45° C Impedance 4.50% (Subject to +/-10% Tolerance) Transformer Oil "A Grade" tested & certified as per IS:335 Standard. Total Losses at 50% Load As per IS standard Total Losses at 100% Load As per IS standard Copper "Sterlite" make- 99.9% Pure Electrolytic Grade. Tapping Mode Off Circuit Tap Changer Basic Insulation Level for HV 75 KVpeak / 28KVrms Basic Insulation Level for LV - / 3 KVrms
Request Callback
Additional Information:
Delivery Time: 10 days
Yes! I am interested
3-Phase Oil-Cooled 400 KVA Distribution Transformer
3-Phase Oil-Cooled Power Transformer by Servokon Systems Limited
This is a reliable and efficient transformer designed to manage high-voltage electricity. It uses oil for cooling, which helps maintain optimal performance and prevents overheating. Suitable for industrial and commercial applications, it efficiently converts electricity from high voltage to usable levels, ensuring a stable power supply. Known for its durability and energy efficiency, this transformer is ideal for heavy-duty use.
Request Callback
Additional Information:
Production Capacity: 50 MVA
Delivery Time: 3-4 Weeks
Yes! I am interested
2000 Kva Distribution Transformer
Ask For Price
Product Price :Get Latest Price Product Brochure
Product Details:
Power
630 kva
Cooling Type
Air Cooled
Phase
3 Phase
AMC Available
Yes
Onsite Support Available
Yes
Single Phase Variac Transformer is a device that allows precise control of AC voltage output. Manufactured by Servokon Systems Limited, this transformer is designed to provide a continuous and adjustable voltage supply, ensuring minimal waveform distortion.
Request Callback
Yes! I am interested
800 Kva Distribution Transformer
Ask For Price
Product Price :Get Latest Price
Product Details:
Power
630 kva
Phase
3 Phase
Onsite Support Available
Yes
Capacity
From 250 KVA to 30 MVA
Voltage Class
433 V, 3.3 kV, 6.6 kV, 11 kV, 22 kV, 33 kV (Any Special Customised Class as per requirement)
Low Voltage
400 V, 440V, 500V, 575V, 750V, 800V 1000V (Any Special Customised Class as per requirement)
Tap Changer
OCTC & OLTC
Cooling-
ONAN, ONAF, OFAF, ONWF, OFWF
An 800 kVA Distribution Transformer from Servokon Systems Limited is a heavy-duty electrical device designed to step down high-voltage electricity from the power grid to a lower voltage suitable for industrial or commercial use. This transformer has a power rating of 800 kilovolt-amperes (kVA), indicating its capacity to handle substantial electrical loads. It operates on a three-phase system, ensuring efficient and balanced power distribution. The transformer utilizes oil cooling to maintain optimal operating temperatures, enhancing its performance and longevity. Constructed with copper windings, it offers high electrical conductivity and durability. Built to international standards, it ensures reliable and safe operation in various industrial settings. The insulation class A rating signifies its ability to withstand high temperatures, making it suitable for demanding environments. Manufactured in India, this transformer reflects Servokon's commitment to quality and innovation in power distribution solutions.
SERVOKON make,Three Phase DISTRIBUTION TRANSFORMER With All other Standard accessories
Make SERVOKON Capacity 63 KVA Input Voltage 11 KV Output Voltage 433 Volts Number of Phase 3 Phase Applicable Standard BIS 1180 L-2 Number of Winding 2 Winding Type of Installation Outdoor Type Frequency 50 Hz Method of Cooling ONAN Terminal Arrangement Bare Bushing for HV Side & for LV Side Vector Group Dyn11 Designed Ambient Temperature 50° C Temperature Rise of Oil 40° C Temperature Rise of Winding 45° C Impedance 4.50% (Subject to +/-10% Tolerance) Transformer Oil "A Grade" tested & certified as per IS:335 Standard. Total Losses at 50% Load As per IS Standard Total Losses at 100% Load As per IS Standard Copper "Sterlite" make- 99.9% Pure Electrolytic Grade. Tapping Mode Off Circuit Tap Changer Basic Insulation Level for HV 75 KVpeak / 28KVrms Basic Insulation Level for LV - / 3 KVrms
We bring forth for our clients a comprehensive range of Distribution Transformer and power distribution transformer that are available with cooling systems with on and off facility. Offered with oil natural air cooling wound with copper conductor, these transformers are suitable for both corrugated tanks and presses steel radiators. Our transformers are appreciated for heavy duty construction and optimum safety.
Features:
High Efficiency
High Durability
Low-temperature rise
Minimum maintenance
Trouble free service
Long life
Taping:On Load Tap Changer to provide +5% to -15% Taps in steps of 1.25% on the H.T. Side. Else, Off Circuit Tap Changer for ± 5% Taps on H.T. Side in steps of 2.5% each.
Request Callback
Yes! I am interested
Servokon Make, Solar Inverter Duty Transformers upto 25 MVA
0.415 KV/11KV, 0.415 KV/22 KV or 0.415 KV/33KV, Copper Wound, Oil Immersed, Outdoor Type, IS 2026 with Tapping Range +5% to -5% in Steps of 2.5% by Off Circuit Tap Changer. Three Phase INVERTER DUTY TRANSFORMER
11/0.690 KV or 33/0.690 KV,(As per Customer requirement) Copper Wound, Oil Immersed(ONAN/ONAF), Outdoor Type/INDOOR TYPE , IS 2026 with Tapping Range +5% to -5% in Steps of 2.5% by Off Circuit Tap Changer. Three Phase Furnace TRANSFORMER
SERVOKON make,100 KVA Three Phase DISTRIBUTION TRANSFORMER With All other Standard accessories.
Make SERVOKON Capacity 100 KVA Input Voltage 11 KV Output Voltage 433 Volts Number of Phase 3 Phase Applicable Standard BIS 1180 L-2 Number of Winding 2 Winding Type of Installation Outdoor Type Frequency 50 Hz Method of Cooling ONAN Terminal Arrangement Bare Bushing for HV Side & for LV Side Vector Group Dyn11 Designed Ambient Temperature 50° C Temperature Rise of Oil 40° C Temperature Rise of Winding 45° C Impedance 4.50% (Subject to +/-10% Tolerance) Transformer Oil "A Grade" tested & certified as per IS:335 Standard. Total Losses at 50% Load As per IS Standard Total Losses at 100% Load As per IS Standard Copper "Sterlite" make- 99.9% Pure Electrolytic Grade. Tapping Mode Off Circuit Tap Changer Basic Insulation Level for HV 75 KVpeak / 28KVrms Basic Insulation Level for LV - / 3 KVrms